Chapter 6. Operation Mode and How to use
6-
8
5) Main application field
Input absolute position value in parameter at all sorts INDEX machine, respectively and sequent
ional operation is executed by START contact of ON,
Manual operation mode : START contact=ON; 1 step operation
Auto operation mode : START contact=ON, continuously sequential operation
6.5 Setting of position, input and output
Parameter Input Output
No. Initial 0 1 2 3 4 0 1 2 3 4
P5-01 Position CMD0 10 0 0 0 0 0 0 0 0 0 0
P5-02 Position CMD1 20 1 0 0 0 0 1 0 0 0 0
P5-03 Position CMD2 30 0 1 0 0 0 0 1 0 0 0
P5-04 Position CMD3 40 1 1 0 0 0 1 1 0 0 0
P5-05 Position CMD4 50 0 0 1 0 0 0 0 1 0 0
P5-06 Position CMD5 60 1 0 1 0 0 1 0 1 0 0
P5-07 Position CMD6 70 0 1 1 0 0 0 1 1 0 0
P5-08 Position CMD7 80 1 1 1 0 0 1 1 1 0 0
P5-09 Position CMD8 90 0 0 0 1 0 0 0 0 1 0
P5-10 Position CMD9 100 1 0 0 1 0 1 0 0 1 0
P5-11 Position CMD10 110 0 1 0 1 0 0 1 0 1 0
P5-12 Position CMD11 120 1 1 0 1 0 1 1 0 1 0
P5-13 Position CMD12 130 0 0 1 1 0 0 0 1 1 0
P5-14 Position CMD13 140 1 0 1 1 0 1 0 1 1 0
P5-15 Position CMD14 150 0 1 1 1 0 0 1 1 1 0
P5-16 Position CMD15 160 1 1 1 1 0 1 1 1 1 0
P5-17 Position CMD16 170 0 0 0 0 1 0 0 0 0 1
P5-18 Position CMD17 180 1 0 0 0 1 1 0 0 0 1
P5-19 Position CMD18 190 0 1 0 0 1 0 1 0 0 1
P5-20 Position CMD19 200 1 1 0 0 1 1 1 0 0 1
P5-21 Position CMD20 210 0 0 1 0 1 0 0 1 0 1
P5-22 Position CMD21 220 1 0 1 0 1 1 0 1 0 1
P5-23 Position CMD22 230 0 1 1 0 1 0 1 1 0 1
P5-24 Position CMD23 240 1 1 1 0 1 1 1 1 0 0
P5-25 Position CMD24 250 0 0 0 1 1 0 0 0 1 1
P5-26 Position CMD25 260 1 0 0 1 1 1 0 0 1 1
P5-27 Position CMD26 270 0 1 0 1 1 0 1 0 1 1
P5-28 Position CMD27 280 1 1 0 1 1 1 1 0 1 1
P5-29 Position CMD28 290 0 0 1 1 1 0 0 1 1 1
P5-30 Position CMD29 300 1 0 1 1 1 1 0 1 1 1
P5-31 Position CMD30 310 0 1 1 1 1 0 1 1 1 1
P5-32 Position CMD31 320 1 1 1 1 1 1 1 1 1 1
Note1) 0: contract OFF, 1: Contact On
Note2) can only use till P5-01-P5-16 when use MPG.
Note3) can only use till P5-01-P5-04 when P8-03=”2”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Higen FDA6000C Series and is the answer not in the manual?

Higen FDA6000C Series Specifications

General IconGeneral
BrandHigen
ModelFDA6000C Series
CategoryServo Drives
LanguageEnglish

Related product manuals