120
● Main power supply exception
● Backup battery exception
● Alarm receiving fault
● Sounder fault
● Low battery of the keyfob
● Others
Arming with Fault
While the arming is stopped with fault, user in level 2 has the permission to arm the system with
fault (forced arming).
Forced arming only takes effect on the current arming operation.
The forced arming operation will be record in the event log.
6.2 Disarming
You can disarm the system with keypad, keyfob, tag, client software, or mobile client.
Disarming Indication
The arming/disarming indicator flashes 30s while the user successfully disarm the system through
the entry/exit route.
The system will report the disarming result after the operation completed.
Entry Delay Duration
Ensure that timer is no longer than 45 seconds in order to comply with EN50131-1.
Early Alarm
If the first instant zone is triggered when the AX PRO is in the status of entry delay, the AX PRO
then enters the early alarm mode.
The early alarm duration can be set (> 30s).
The AX PRO will reports the alarm only if the alarm event lasts over the duration of early alarm
with the addition of entry delay.
6.3 SMS Control
You can control the security system with SMS, and the command is shown below.
SMS format for Arming/disarming/silencing alarm:
{Command} + {Operation Type} + {Target}
Command: 2 digits, 00- Disarming, 01- Away arming, 02- Stay arming, 03- Silencing alarm
Operation type: 1- Area Operation
Target: No more than 3 digits, 0-Operation for all areas, 1-Operation for area 1(zone1), and the
rest can be deduced by the analogy.