115
Figure 5-38. Module Locking Settings
3. Set the following parameters of the selected module.
Retry Times before Auto-Lock
If a user continuously tries to authentication a password for more than the configured
attempts permitted, the keypad will be locked for the programmed duration.
Auto-lock Time
Set the locking duration when the keypad is locked. After the configured duration, the keypad
will be unlocked.
4. Click Save.
5.4 Report to ARC (Alarm Receiving Center)
AX PRO wireless control panel is designed with transceiver built in following the guidance of EN
50131-10 and EN 50136-2. Category DP2 is provided with primary network interface of LAN/WiFi
and secondary network interface of GPRS or 3G/4G LTE. ATS (Alarm Transmission system) is
designed to always use LAN/Wi-Fi network interface when available to save mobile data usage.
The secondary network interface provides resilience and reliability during mains power failure.
Setup ATS in Transceiver of Receiving Center
Steps:
1. Login to the web client of the alarm receiver.
2. Click ConfigurationIP Reception, and create a receiving server as shown below.

Table of Contents

Other manuals for HIKVISION AX PRO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION AX PRO and is the answer not in the manual?

HIKVISION AX PRO Specifications

General IconGeneral
BrandHIKVISION
ModelAX PRO
CategorySecurity System
LanguageEnglish

Related product manuals