Name
Edit the card reader name as desired.
Alarm Output Acve Time
How long the alarm output will last aer triggered.
4.
Click OK.
5.
Oponal: Set the switch on the upper right corner to ON to trigger the alarm output.
Congure Parameters for Lane Controller
Aer adding the lane controller to the client, you can congure its parameters for passing through
the lane.
Before You Start
Add access control device to the client.
Steps
1.
Click Access Control → Advanced
Funcon → Device Parameter to enter Parameter Sengs
page.
2.
In the device list on the
le, select a lane controller and you can edit the lane controller's
parameters on the right.
3.
Edit the parameters.
Passing Mode
Select the controller which will control the barrier status of the device.
Alarm Voice Prompt Time
Duraon
Set how long the audio will last, which is played when an alarm is triggered .
Note
0 refers to the alarm audio will be played unl the alarm is ended.
Temperature Unit
Select the temperature unit that displayed in the device status.
Lightboard Brightness
Adjust the brightness of the device light.
Memory Mode
Mulple cards presenng for mulple persons passing is allowable when enabling the
memory mode. When the passing person's number exceeds the card presenng number, or
aer the latest person passing with no other person passing within the door open duraon,
the door will closed automacally.
4.
Click OK.
DS-K3G200(L)X Series Tripod Turnsle