Hitachi Advanced Server HA820 G2 User Guide 108
11.
Install the access panel.
12.
Side the server into the rack.
13.
Connect each power cord to the server.
14.
Connect each power cord to the power source.
15.
Power up the server.
Installing a front/tertiary 2 SFF NVMe/SAS/SATA stackable drive cage
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
•
T-10 Torx screwdriver
•
The components included with the hardware option kit
•
This installation requires a universal media bay.
Procedure
1.
Power down the server.
2. Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
•
Extend the server from the rack.
•
Remove the server from the rack.
4.
Remove the access panel.
5.
Remove the front bay blank.
6.
Remove the optical disc drive tray from the universal media bay.