Hitachi Advanced Server HA820 G2 User Guide 90
11.
If needed, connect data cables to the drive backplane.
The installation is complete.
Installing tertiary risers
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
•
The components included with the hardware option kit
•
T-10 Torx screwdriver
•
A tertiary riser cage is required to install this option.
Procedure
1.
Power down the server.
2.
Do one of the following:
•
Disconnect each power cord from the power source.
•
Disconnect each power cord from the server.
3.
Do one of the following:
•
Extend the server from the rack.
•
Remove the server from the rack.
4.
Remove the access panel.
5.
Remove the riser cage.
6.
Install the riser.
7.
If needed, install an expansion board.
8.
If needed, connect data cables to the riser or expansion board.