GENERAL CHECK
ELECTRICAL AND CONTROL SETTINGS
6.1 General check
Make sure that the following condions related to power supply installaon are sased:
The power capacity of the electrical installaon is large enough to support the power
demand of the YUTAKI system (outdoor unit + indoor unit + DHW tank (if apply)).
The power supply voltage is within ±10% of the rated voltage.
The impedance of the power supply line is low enough to avoid any voltage drop of more
than 15% of the rated voltage.
Following the Council Direcve 2004/108/EC, relang to electromagnec compability, the
table below indicates the Maximum permied system impedance Z
max
at the interface point of
the users supply, in accordance with EN61000‑3‑11.
Model Power supply Operaon mode Z
max
(Ω)
RWM‑(1.5‑3.0)R2E
~ 230V 50Hz
Without electric heater
With electric heater
With DHW tank heater
With electric and DHW tank heaters 0.30
3N~ 400V 50Hz
Without electric heater
With electric heater
With DHW tank heater
With electric and DHW tank heaters
NOTE
The data corresponding to DHW tank heater is calculated in combinaon with the domesc hot
water tank accessory “DHWT‑(200/300)S‑3.0H2E”.
The status of Harmonics for each model, regarding compliance with IEC 61000‑3‑2 and
IEC 61000‑3‑12, is as follows:
Status regarding compliance with IEC 61000‑3‑2 and IEC 61000‑3‑12
Models
YUTAKI S
Equipment complying with IEC 61000‑3‑2 (*): Professional use tbc
Equipment complying with IEC 61000‑3‑12
Installaon restricons may be applied by supply authories in relaon to harmonics
Check to ensure that exisng installaon (main power switches, circuit breakers, wires,
connectors and wire terminals) already complies with the naonal and local regulaons.
The use of the DHW tank heater is disabled as factory seng. If it is desired to enable the DHW
tank heater operaon during normal indoor unit operaon, adjust the DSW4 pin 3 of the PCB1 to
the ON posion and use the adequate protecons. Refer to the secon “6.2 Electrical connecon”
for the detailed informaon.

Table of Contents

Other manuals for Hitachi YUTAKI S Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi YUTAKI S Series and is the answer not in the manual?

Hitachi YUTAKI S Series Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
RefrigerantR410A
Cooling Capacity2.5 - 16 kW
Operating Temperature Range (Cooling)46°C
Indoor Unit DimensionsVaries by model
Outdoor Unit DimensionsVaries by model
Noise LevelVaries by model

Related product manuals