SERVICING YOUR GENERATOR
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete
draining.
1. Place a suitable container below the engine to catch the used oil,
and then remove the oil filler cap, 12×15 mm drain plug, and sealing
washer.
2. Allow the used oil to drain completely, and then reinstall the 12×15
mm drain plug and a new sealing washer. Tighten the plug securely.
TORQUE: 16.6 lbf·ft (22.5 N·m, 2.25 kgf·m)
3. With the generator in a level position, fill with the recommended oil
to the outer edge of the oil filler neck (see page 43).
Maximum oil capacity: 1.2 US qt (1.1 L)
4. Reinstall the oil filler cap securely.
Wash your hands with soap and water after handling used oil.
Improper disposal of engine oil can be harmful to the environment. If
you change your own oil, please dispose of it properly. Put it in a
sealed container, and take it to a recycling center. Do not discard it in a
trash bin, dump it on the ground, or pour it down a drain.
UPPER LIMIT
OIL FILLER CAP
SEALING
WASHER
(Replace)
12×15 mm
OIL DRAIN PLUG
31Z306120.book 44 ージ 015年11月27日 金曜日 午前10時25分

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EG6500CL and is the answer not in the manual?

Honda EG6500CL Specifications

General IconGeneral
BrandHonda
ModelEG6500CL
CategoryInverter
LanguageEnglish

Related product manuals