OPERATION
STARTING THE ENGINE
To prevent a possible fire, keep the generator at least 1 meter away from
building walls and other equipment during operation. Do not place
flammable objects close to the engine.
Operating this generator less than 1 meter from a building or other
obstruction can cause overheating and damage the generator.
For proper cooling, allow at least 1 meter of empty space above and
around the generator.
Keep all cooling holes open and clear of debris, mud, water, etc.
Cooling holes are located on the side panel, the control panel, and
the bottom of the generator. If the cooling holes are blocked, the
generator may overheat and damage the engine, inverter, or
windings.
Refer to
SAFE OPERATING PRECAUTIONS
on page 22 and perform the
IS YOUR GENERATOR READY TO GO?
checks (see page 20).
Refer to the
AC OPERATION
(see page 28),
AC PARALLEL OPERATION
(see page 31) or
DC OPERATION
(see page 37) for connecting loads to
the generator.
1. Make sure that all appliances are disconnected from the AC receptacle.
2. Turn the fuel filler cap vent lever to the ON position.
FUEL FILLER CAP VENT LEVER
ON
ON
32Z446000.book Page 23 Friday, February 2, 2018 3:46 PM