Getting Started
Part No.: 4417584_Rev12 Configuration Manual
CIU 888 3 - 49
3.2.7.2 Configuring tank under Ethernet field port:
On the FTEA port node, click and choose Add > Tank
The “Add site element” window appears
In the name box, type the name and click OK.
The tank1 node is created and displayed under ethernet filed port.
NOTE: For configuring tank refer Section 3.2.7.1
Browse Click ‘Browse’ to select a water tank capacity table.
Selected file is copied to the data environment of the
selected site (C:\Users\Public\Documents\Honey-
well\CIU 888 Service Tool\SiteData-
base\<sitename>\STR.
The copied file gets the name [Water Tank name].txt.
View Click ‘View’ to view the water tank capacity table.
Note: A selected water tank capacity table file is only accepted if the used
engineering units match the global selected engineering units of the site
configuration.
Note: In case of a separate water sump in the tank, a water TCT can be used and
water TCT should be based on geometry and dimensions of the sump.
Properties Description