Lynx Plus Series Installation and Setup Guide
- 44 -
80 Device Programming Menu Mode
Upon a Zone Type or System Operation - Zone Type/System Operation: Instead of using a RESTORE
ZONE LIST, a specific zone (response) type or system operation action can be selected to de-activate the
device.
If a specific ZONE TYPE is chosen, any zone of that response type that restores from a previous alarm,
trouble, or fault condition will cause the device to de-activate.
If a SYSTEM OPERATION is chosen, that operation will cause the device to de-activate.
During normal system operation, any devices may be:
Manually started by keypad entry of: Code* + [#] + 4 + nn; OR
Manually stopped by keypad entry of: Code* + [#] + 7 + nn, where nn = the 2-digit device
number to be controlled.
* Code is required for devices 07 and 08. For devices 01-06, code is not required. See User Manual for more
information.
Programming Powerline Carrier Devices
While in Program mode, press 80 to enter Device Programming Menu Mode. This mode is used to
program all output devices used in the system. Refer to the output device table for
80 on the
separate programming form when programming output devices.
Note: The House ID of the Powerline Carrier Devices must be entered in data field 25.
The following explains these prompts in detail. The left two columns identify the prompts and list the
available entries. The right-most column provides a further explanation of the entries.
Note: Entering a number other than one specified will give unpredictable results.
ZT16 is only available on the LynxSIA Plus version of the control panel.
80
8080
80
DEVICE
DEVICE DEVICE
DEVICE
PROG
PROG PROG
PROG
MENU
MENUMENU
MENU
Powerline Carrier Device Programming
Entering 0 exits mode, upon which this prompt blinks, indicating that the mode is
inactive. Entering 1 advances to the next prompt below.
SELECTIONS
0 = exit mode
1 = enter mode
A01
A01A01
A01
DEVICE
DEVICE DEVICE
DEVICE
NUMB
NUMBNUMB
NUMBER
ERER
ER
Device Number
Enter the 2-digit device number to be programmed.
SELECTIONS
01-08 = X10 device number to be programmed
09-16 = Multi-mode (e-mail) event triggers
[] = continue
00 = exit Device Programming mode
b
DEVICE
DEVICE DEVICE
DEVICE
ACTION
ACTIONACTION
ACTION
Device Action
Enter the 1-digit device action (0-3) for the device being programmed (current action is
displayed).
Notes: (1) If “3” is entered (pulse), only up to 3 different devices can be pulsed if one of
the devices is a siren/horn (X10 Powerhouse Security model SH10A). In
addition, the siren/horn cannot be manually activated using the lights on/lights
off keypad commands.
(2) If using an X10 Powerhouse Security SH10A siren, you must use device action
“3” and change the device action default to “3” (if using default table 2 or 4).
SELECTIONS
0= No response
1 = Close for 2 seconds
2 = Close and Stay Closed
3 = Continuous Pulse on & off (1 sec ON, 1 sec OFF)
[] = continue
[#] = return to previous prompt

Table of Contents

Other manuals for Honeywell Lynx Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Lynx Plus Series and is the answer not in the manual?

Honeywell Lynx Plus Series Specifications

General IconGeneral
BrandHoneywell
ModelLynx Plus Series
CategorySecurity System
LanguageEnglish

Related product manuals