EasyManuals Logo
Home>Honeywell>Security System>Lynx Plus Series

Honeywell Lynx Plus Series Installation And Setup Guide

Honeywell Lynx Plus Series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
Lynx Plus Series Installation and Setup Guide
- 45 -
80 Device Programming Menu Mode
C
CC
C
START
START START
START
EVENT
EVENT EVENT
EVENT
TYPE
TYPETYPE
TYPE
Start Event Type
Enter the 1-digit start event type (0-3) to activate the device being programmed. A zone
list must be used in conjunction with an event. If a zone type/system operation is to be
used instead of an event, enter 0.
SELECTIONS
0 = Not used
1 = Alarm
2 = Fault
3 = Trouble
[] = continue
[#] = return to previous prompt
d
START
START START
START
ZONE
ZONE ZONE
ZONE
LIST
LISTLIST
LIST
Start Zone List
If a zone list will be used to start the device action, enter the 1-digit zone list number for
the device being programmed.
SELECTIONS
1-3 = zone list number (to be programmed in field 81)
0 = zone list not used for this device
[] = continue
[#] = return to previous prompt
E
EE
E
START
STARTSTART
START
ZONE
ZONE ZONE
ZONE
TYPE
TYPETYPE
TYPE
Start Zone Type
If a zone type or system operation will be used to start the device action, enter the
appropriate 2-digit code for the device being programmed (see table that follows).
Choices for zone types
00 = Not Used 07 = 24 Hr Audible
01 = Entry/Exit #1 08 = 24 Hr Aux
02 = Entry/Exit #2 09 = Fire without verification
03 = Perimeter 10 = Interior w/Delay
04 = Interior Follower 14 = Carbon Monoxide
05 = Trouble Day/Alarm Night 16 = Fire with verification (SIA Only)
06 = 24 Hr Silent 24 = Silent Burglary
Choices for system operation
20 = ArmingStay 38 = Chime
21 = ArmingAway 52 = Kissoff
22 = Disarm. (Code + OFF) 39 = Any Fire Alarm
31 = End of Exit Time 40 = Bypassing
32 = Start of Entry Time 42 = System Battery Low
33 = Any Alarm (except ZT 08, 09, 14 or 16) 43 = Communications Failure
36 = At Bell Timeout** 58 = Duress
** Or at Disarming (which ever occurs earlier)
SIA ZT 16 must be used in SIA fire applications.
SELECTIONS
01-58 = zone type to start this device action (select only those that are applicable
00 = zone type not used for this device
[] = continue
[#] = return to previous prompt
F
FF
F
STOP
STOP STOP
STOP
ZONE
ZONE ZONE
ZONE LIST
LIST LIST
LIST
Stop Zone List
If a zone list will be used to STOP, or restore, the device action, enter the zone list
number 1, 2, or 3 (to be programmed in 81 mode). If not used, enter 0.
SELECTIONS
1-3 = zone list to stop this device action
0 = zone list not used
[] = continue
[#] = return to previous prompt

Table of Contents

Other manuals for Honeywell Lynx Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Lynx Plus Series and is the answer not in the manual?

Honeywell Lynx Plus Series Specifications

General IconGeneral
BrandHoneywell
ModelLynx Plus Series
CategorySecurity System
LanguageEnglish

Related product manuals