21
Figure 25 Connecting the power cord for a PSR150-A1 power supply (2)
Connecting the power cord for a PSR150-D1 power supply
CAUTION:
Connect the other ends of the wires for a PSR150-D1 power supply to a
48 VDC power source,
with the negative wire ( or L–) to the negative terminal () and the positive wire (+ or M/N
) to the
positive terminal (+).
To use an HPE RPS to supply power to the power supply, use a compatible RPS power cord to
connect the RPS to the power supply.
The power cord color code scheme in Figure 26 is for illustration only. The cable delivered for
your country or region might use a different color scheme. When you connect the power cord,
always identify the polarity symbol on its wires.
To connect the power cord for a PSR150-D1 power supply:
1. Correctly orient the plug at one end of the cable with the power receptacle on the power supply,
and insert the plug into the power receptacle. See callout 1 in Figure 26.
If you cannot insert the plug into the receptacle, re-orient the plug rather than use excessive
force to push it in.
2. Tighten the screws on the plug with a flat-blade screwdriver to secure the plug in the power
receptacle. See callout 2 in Figure 26.
3. Connect the other end of the power cord to a 48 VDC power source or an RPS.
1
2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP FlexNetwork 5140 EI Series and is the answer not in the manual?

HP FlexNetwork 5140 EI Series Specifications

General IconGeneral
BrandHP
ModelFlexNetwork 5140 EI Series
CategorySwitch
LanguageEnglish

Related product manuals