Configuring for Network Management Applications
Using SNMP Tools To Manage the Switch
If the sending agent does not receive an SNMP response back from the SNMP
Manager within the timeout period, the inform request may be resent, based
on the retry count value.
You must specify an IP address that will receive the notifications and the
community name.
Note The retries and timeout options are not used when using trap requests.
ProCurve Switch# show snmp-server
SNMP Communities
Community Name MIB View Write Access
---------------- -------- ------------
public Manager Unrestricted
Trap Receivers
Link-Change Traps Enabled on Ports [All] : All
Send Authentication Traps [No] : No
Address Community Events Sent Notify Type Retry Timeout
--------------------- --------------- ----------- ----------- ----- --------
15.28.333.456 guest All inform 3 15
Excluded MIBs
Snmp Response Pdu Source-IP Information
Selection Policy : Default rfc1517
Trap Pdu Source-IP Information
Selection Policy : Default rfc1517
Figure 13-10. Example Showing SNMP informs Option Enabled