EasyManuals Logo
Home>Huawei>Server>TaiShan 200 Series

Huawei TaiShan 200 Series User Manual

Huawei TaiShan 200 Series
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
iME Version: 0.66
BIOS Version: (U75)0.90
-------------- Mother Board INFO ---------------
Mainboard BoardID: 0x00b9
Mainboard PCB: .A
--------------- Riser Card INFO ----------------
Riser1 BoardName: BC11PRUCRiser1
BoardID: 0x0090
Riser1 PCB: .A
Riser2 BoardName: BC82PRNE
Riser2 BoardID: 0x0032
Riser2 PCB: .A
------------------- HDD Backplane INFO -------------------
Disk BP1 BoardName: BC11THBQ
Disk BP1 BoardID: 0x0073
Disk BP1 PCB: .A
Disk BP1 CPLD Version:(U3)1.10
-------------------- IO Board INFO -------------------
IOBoard5 ProductName: BC82IOBA
IOBoard5 BoardID: 0x0069
IOBoard5 PCB: .A
IOBoard5 CPLD Version: (U12)0.01
CPLD Version: complex programmable logical device (CPLD) version
of the server
BIOS Version: BIOS version of the server
Active iBMC Version: active iBMC version of the server
Backup iBMC Version: backup iBMC version of the server
e. Query the health status of the server.
iBMC:/->ipmcget -d health
System in health state
If "System in health state" is displayed, no further action is required.
If alarm information is displayed, go to the next step.
f. Query any generated alarms.
iBMC / # ipmcget -d healthevents
Event Num | Event Time | Alarm Level | Event Code | Event Description
1 | 2019-02-10 00:52:23 | Minor | 0x12000021 | get description failed.
2 | 2019-02-10 01:37:42 | Minor | 0x12000013 | Failed to obtain data of the air inlet
temperature.
3 | 2019-02-10 00:52:23 | Minor | 0x12000019 | Right mounting ear is not present.
4 | 2019-02-10 00:52:19 | Major | 0x28000001 | The SAS or PCIe cable to front disk
backplane is incorrectly connected.
g. Clear alarms. For details, see the
TaiShan Rack Server iBMC Alarm
Handling
.
----End
5.10.6 Changing Initial Passwords
Change the following initial user passwords:
Initial password of the default iBMC user
Initial password for the iBMC U-Boot
TaiShan 200 Server
User Guide (Model 2280) 5 Install and Congure
Issue 04 (2020-01-16) Copyright © Huawei Technologies Co., Ltd. 79

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei TaiShan 200 Series and is the answer not in the manual?

Huawei TaiShan 200 Series Specifications

General IconGeneral
BrandHuawei
ModelTaiShan 200 Series
CategoryServer
LanguageEnglish

Related product manuals