6-48 Powermax105 Operator Manual
65 A Unshielded cutting (Stainless Steel)
Air flow rate – slpm/scfh
Hot 175 / 370
Cold 209 / 443
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
2
2.0
5.0 250
0.1 7950 117 10300 116
3 0.2 6600 118 8500 117
4
0.5
5050 119 6500 119
6 2300 121 3070 121
8 0.7 1400 123 1900 122
10 6.0 300 0.7 920 126 1250 123
12
Edge Start
710 130 925 127
16 430 135 500 133
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
inches inches inches % seconds ipm Volts ipm Volts
16GA
0.08
0.20 250
0.1
340 116 437 115
10GA 235 118 304 118
3/16 0.2 150 120 194 120
1/4 0.5 75 121 100 121
3/8 0.24 300 0.7 38 125 52 122
1/2
Edge Start
25 132 32 129
5/8 17 135 20 133