Power SuPPly SetuP
2-8 Powermax105 Operator Manual
Three-phase power cord and plug installation
Powermax105 power supplies are shipped with the following power cords:
• CSA models: 6 AWG 4-wire power cord
• 230–400 V CE: 10 mm
2
, 4-wire HAR power cord
• 380 V CCC/230–400 V CE ships without a power cord
Note: To maintain CE certification, install power cord kit 228886.
• 400 V CE: 6 mm
2
, 4-wire HAR power cord
• 380 V CCC: 6 mm
2
, 4-wire CCC power cord (some models ship without a power cord)
To operate the Powermax105, use a plug that meets national and local electrical codes. The plug must be connected to
the power cord by a licensed electrician.
Strip and prepare the power cord wires as shown below.
L1
L3
L2
L2
L1
L3
Ground
6 mm (.25 in.)
419 mm
(16.5 in.)
203 mm
(8 in.)
CSA
Route lead through strain
relief and tighten

Table of Contents