2-6 Powermax105 Operator Manual
Power connection for the Powermax105
Powermax105 3-phase systems include the following models:
• The 200–600 V CSA model is a universal power supply that can automatically adjust to operate with
ACvoltages from 200 to 600 V.
• The 230–400 V CE model can automatically adjust from 230 to 400 V.
• The 380 V CCC/230–400 V CE model can automatically adjust from 230 to 400 V.
Note: To maintain CE certification, install power cord kit 228886.
• The 400 V CE model is 400 V only.
• The 380 V CCC model is 380 V only.
The rated output is 30–105 A, 160 VDC.
200–600 V CSA
Input voltage (V) 200 208 240 480 600
Input current (A) at rated output (16.8 kw) 58 56 49 25 22
Input current (A) at arc stretch 82 82 78 40 35
Fuse, slow-blow (A) 80 80 80 40 40
230–400 V CE
Input voltage (V) 230 400
Input current (A) at rated output (16.8 kw) 50 29
Input current (A) at arc stretch 80 46
Fuse, slow-blow (A) 80 50