6-18 Powermax105 Operator Manual
105 A Shielded cutting (Mild Steel)
Air flow rate – slpm/scfh
Hot 217 / 460
Cold 250 / 530
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
6
3.2
6.4 200
0.5 4140 144 5090 145
8
0.75
3140 145 3870 145
10 2260 145 2790 145
12 1690 145 2060 148
16
1.0
1060 149 1310 149
20 780 152 940 152
25
Edge Start
550 159 580 158
30 370 162 410 161
32 350 166 370 161
35 290 168 320 165
40 190 173 210 170
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce Height
Pierce
Delay Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
inches inches inches % seconds ipm Volts ipm Volts
1/4
0.125
0.25 200
0.5 156 144 192 145
3/8
0.75
94 145 116 145
1/2 62 146 76 148
5/8
1.0
42 149 52 149
3/4 33 151 40 150
7/8 1.25 26 154 30 157
1
Edge Start
21 160 22 158
1-1/8 15 162 17 160
1-1/4 14 166 15 161
1-1/2 9 171 10 168