Powermax105 Operator Manual 2-9
Extension cord recommendations
Any extension cord must have an appropriate wire size for the cord length and system voltage. Usea cord that meets
national and local codes.
The table on the next page provides the recommended gauge sizes for various lengths and input voltages. The lengths
in the tables are the length of the extension cord only; they do not include the power supply’s power cord.
Extension cord specifications
Extension cord length
< 3 m
(<10ft)
3–7.5 m
(10–25ft)
7.5–15 m
(25–50ft)
15–30 m
(50–100ft)
30–45 m
(100–150ft)
200–600 V CSA
Input voltage (VAC) Phase mm
2
(AWG) mm
2
(AWG) mm
2
(AWG) mm
2
(AWG) mm
2
(AWG)
200–240 3 16 (6) 16 (6) 16 (6) 25 (4) 35 (2)
480–600 3 6 (10) 6 (10) 6 (10) 6 (10) 6 (10)
230–400 V CE
Input voltage (VAC) Phase mm
2
mm
2
mm
2
mm
2
mm
2
230 3 16 16 16 25 25
400 3 10 10 10 10 10
380 V CCC/230–400 V CE
Input voltage (VAC) Phase mm
2
mm
2
mm
2
mm
2
mm
2
230 3 16 16 16 25 25
400 3 10 10 10 10 10
380 3 10 10 10 10 10
400 V CE
Input voltage (VAC) Phase mm
2
mm
2
mm
2
mm
2
mm
2
400 3 10 10 10 10 10
380 V CCC
Input voltage (VAC) Phase mm
2
mm
2
mm
2
mm
2
mm
2
380 3 10 10 10 10 10