6-26 Powermax105 Operator Manual
65 A Shielded cutting (Mild Steel)
Air flow rate – slpm/scfh
Hot 175 / 370
Cold 209 / 443
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
2
1.5
3.8 250
0.1 6050 124 7000 121
3 0.2 5200 125 6100 123
4
0.5
4250 125 5100 124
6 2550 127 3240 127
8 1700 129 2230 128
10
4.5 300
0.7 1100 131 1500 129
12 1.2 850 134 1140 131
16 6.0 400 2.0 560 138 650 136
20
Edge Start
350 142 450 142
25 210 145 270 145
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Best Quality Settings Production Settings
Cut Speed Voltage Cut Speed Voltage
inches inches inches % seconds ipm Volts ipm Volts
16GA
0.06
0.15 250
0.1
260 123 294 121
10GA 190 125 224 123
3/16 0.2 140 126 168 125
1/4 0.5 90 127 116 127
3/8 0.7 45 130 62 129
1/2 0.18 300 1.2 30 135 40 132
5/8 0.24 400 2.0 23 138 26 136
3/4
Edge Start
15 141 19 141
7/8 12 143 14 143
1 8 145 10 145