Note: Read the Danger and caution notices in the “MAPPWR” on page 364 introduction before performing
this procedure.
1. Record the error code and the location codes that sent you to this procedure.
2. Power off the system. See Power on/off the system and logical partitions. Then, examine the amber
logic-power LEDs of all installed processor subsystem DCAs.
3. Are all amber logic-power LEDs of all installed processor subsystem DCAs off?
v Yes: Continue with the next step.
v No: Replace the DCA that has the amber logic power LED that did not turn off. See symbolic FRU
“DCAPWR” on page 324.
4. Pull out the following books about 25 mm (1 inch), if present. See Models 870 and 890 - Memory
books and memory blanks.
v Memory book 0 at location M18
v Memory book 1 at location M24
v Memory book 2 at location M07
v Memory book 3 at location M02
5. Power on the system. See Power on/off the system and logical partitions.
6. Did the system stop with the same error code as recorded in step 1 (See page 389)?
v Yes: Go to step 12 (See page 389).
v No: Continue with the next step.
7. One of the books just removed is defective.
a. Power off the system. See Power on/off the system and logical partitions.
b. Make sure all amber logic-power LEDs of all installed processor subsystem DCAs are off.
8. Reinsert one of the books that is pulled out and listed in step 4 (See page 389).
9. Power on the system. See Power on/off the system and logical partitions.
10. Did the system stop with the same error code as recorded in step 1 (See page 389)?
v Yes: The book just reinserted is defective. Replace it. Return the system to its original
configuration. See Verify the repair.
This ends the procedure.
v No: Continue with the next step.
11.
Have all the books listed in step 4 (See page 389) been reinserted?
v Yes: The symptom has changed. Return the system to its original configuration. See Verify the
repair.
This ends the procedure.
v No: Go to step 8 (See page 389).
12. Power off the system. See Power on/off the system and logical partitions. Then, examine the amber
logic-power LEDs of all installed processor subsystem DCAs.
13. Are all amber logic-power LEDs of all installed processor subsystem DCAs off?
v Yes: Continue with the next step.
v No: Replace the DCA that has the amber logic power LED that did not turn off. See symbolic FRU
“DCAPWR” on page 324.
14.
Pull out the following books about 25 mm (1 inch), if present. See Models 870 and 890 - Memory
books and memory blanks.
v Memory book 4 at location M25
v Memory book 5 at location M08
v Memory book 6 at location M01
v Memory book 7 at location M17
15.
Power on the system. See Power on/off the system and logical partitions.
Analyze hardware problems 389

Table of Contents

Other manuals for IBM iSeries 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 800 and is the answer not in the manual?

IBM iSeries 800 Specifications

General IconGeneral
BrandIBM
ModeliSeries 800
CategoryServer
LanguageEnglish

Related product manuals