v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, “Parts listing, System x3550 M3 Types 4254 and 7944,” on page 159 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
v Go to the IBM support Web site at http://www.ibm.com/systems/support/ to check for technical
information, hints, tips, and new device drivers or to submit a request for information.
Symptom Action
The OVER SPEC LED on the
light path diagnostics panel is
lit, and the 12v channel E LED
on the system board is lit.
1. Turn off the server and disconnect the power from the server.
2. Remove the PCI riser card from PCI riser connector 2 and the microprocessor
in socket 2.
3. Restart the server to see whether the problem remains.
4. Reinstall each device that you removed in step 2 one at a time, starting the
server each time, to isolate the failing device.
5. Replace any failing device.
6. (Trained service technician only) Replace the system board.
The OVER SPEC LED on the
light path diagnostics panel is
lit, and the 12v channel AUX
LED on the system board is lit.
1. Turn off the server and disconnect the power from the server.
2. Remove all PCI Express and PCI-X cards, all PCI riser cards, the operator
information panel, and the Ethernet adapter (if installed).
Note: The server will not power-on when the microprocessor in socket 1 or 2
is not installed in the server. (Trained service technician only) Toggle the switch
block (SW4), bit 3 to allow the server to power-on. See “System-board switches
and jumpers” on page 18 for the location of the SW4 switch block on the
system board.
3. Restart the server to see whether the problem remains.
4. Reinstall each device that was removed in step 2 one at a time, starting the
server each time, to isolate the failing device.
5. Replace any failing device.
6. (Trained service technician only) Replace the system board.
The server does not turn off.
1. Determine whether you are using an Advanced Configuration and Power
Interface (ACPI) or a non-ACPI operating system. If you are using a non-ACPI
operating system, complete the following steps:
a. Press Ctrl+Alt+Delete.
b. Turn off the server by pressing the power-control button and hold it down
for 5 seconds.
c. Restart the server.
d. If the server fails POST and the power-control button does not work,
disconnect the power cord for 20 seconds; then, reconnect the power cord
and restart the server.
2. If the problem remains or if you are using an ACPI-aware operating system,
suspect the system board.
The server unexpectedly shuts
down, and the LEDs on the
operator information panel are
not lit.
See “Solving undetermined problems” on page 155.
98 IBM System x3550 M3 Types 4254 and 7944: Problem Determination and Service Guide