EasyManuals Logo
Home>IBM>Server>System x3550 M3 Type 4254

IBM System x3550 M3 Type 4254 Problem Determination And Service Guide

IBM System x3550 M3 Type 4254
318 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #229 background imageLoading...
Page #229 background image
Note: The procedure below describes how to remove a hot-swap ac power supply,
for instructions on how to remove a hot-swap dc power supply, refer to the
documentation that comes with the dc power supply.
To remove a hot-swap ac power supply, complete the following steps:
1. Read the safety information that begins on page vii and “Installation guidelines”
on page 167.
2. If only one power supply is installed, turn off the server and peripheral devices
and disconnect all power cords.
3. If the server is in a rack, at the back of the server, pull back the cable
management arm to gain access to the rear of the server and the power supply.
4. Press and hold the release tab to the left. Grasp the handle and pull the power
supply out of the server.
5. If you are instructed to return the power supply, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
Chapter 5. Removing and replacing server components 211

Table of Contents

Other manuals for IBM System x3550 M3 Type 4254

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M3 Type 4254 and is the answer not in the manual?

IBM System x3550 M3 Type 4254 Specifications

General IconGeneral
BrandIBM
ModelSystem x3550 M3 Type 4254
CategoryServer
LanguageEnglish

Related product manuals