450 IBM eX5 Implementation Guide
Figure 9-1 shows the location of the available ports to manage the IMM on the x3690 X5.
Figure 9-1 Ports over which the IMM can be managed out-of-band on an x3690 X5
Figure 9-2 shows the location of the ports available to manage the IMM on the x3850 X5.
Figure 9-2 Ports over which the IMM can be managed out-of-band on an x3850 x5
To enable the IMM to use Ethernet port 1, you must complete the following instructions:
1. Boot up the server and press F1 when prompted.
2. Select System Settings from the System Configuration and Boot Management menu.
3. Select Integrated Management Module from the System Settings menu.
4. Select Network Configuration from the Integrated Management Module. This menu
allows you to configure the network settings for the IMM. Also, you can configure the IMM
to share the use of Ethernet port 1 for out-of-band management from this menu, as shown
in Figure 9-3 on page 451.
Enabling Ethernet port 1: The onboard Ethernet port 1 is not shared for use with the
IMM, by default. You must enable this feature in the Unified Extensible Firmware Interface
(UEFI) of the server in both the x3690 X5 and the x3850 X5. The following sections contain
the configuration instructions.
Systems management port Ethernet port 1
Systems management portEthernet port 1

Table of Contents

Other manuals for IBM System x3850 X5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3850 X5 and is the answer not in the manual?

IBM System x3850 X5 Specifications

General IconGeneral
BrandIBM
ModelSystem x3850 X5
CategoryServer
LanguageEnglish

Related product manuals