Replacing the air baffle
This procedure applies only to 4U server models with non-hot-swap power
supplies.
To install the air baffle on 4U server models with non-hot-swap power supplies,
complete the following steps.
1. Read the safety information in “Safety” on page vii and “Installation
guidelines” on page 35.
2. Align the tabs on the air baffle with the slots on the chassis.
3. Lower the air baffle into the server.
Attention:
v Make note of the microprocessor power cable routing, as the cable may
interfere with the air baffle installation.
v Make sure that the tabs on the air baffle are inserted into the holes on the
chassis and no cables are not caught or pinched.
v For proper cooling and airflow, reinstall the air baffle before you turn on the
server. Operating the server with the air baffle removed might damage server
components.
Microprocessor power cable
Figure 83. Microprocessor power cable routing when installing air baffle for 4U server model
with non-hot-swap power supplies
Chapter 6. Removing and replacing components 185