4. Install the adapters.
5. Stand the server back up in its vertical position.
6. Install and lock the side cover (see “Replacing the side cover” on page 182).
7. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Removing the non-hot-swap power supply
This procedure applies only to 4U server models with non-hot-swap power
supplies.
When you remove or install a fixed power supply, observe the following
precautions.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any component
that has this label attached. There are no serviceable parts inside these
components. If you suspect a problem with one of these parts, contact a service
technician.
To remove a non-hot-swap power supply on 4U server models with non-hot-swap
power supplies, complete the following steps.
Hinge pin
Rear adapter
retention
bracket
Pin hole
Figure 174. Rear adapter-retention bracket installation for 5U server model with hot-swap
power supplies
Chapter 6. Removing and replacing components 259

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3100 M5 Type 5457 and is the answer not in the manual?

IBM x3100 M5 Type 5457 Specifications

General IconGeneral
BrandIBM
Modelx3100 M5 Type 5457
CategoryServer
LanguageEnglish

Related product manuals