6. Install the heat sink onto the microprocessor as described in “Replacing the
microprocessor and heat sink” on page 304.
Installing the non-hot-swap power supply
This procedure applies only to 4U server models with non-hot-swap power
supplies.
Statement 8
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any component
that has this label attached. There are no serviceable parts inside these
components. If you suspect a with one of these parts, contact a service
technician.
To install a non-hot-swap power supply on 4U server models with non-hot-swap
power supplies, complete the following steps.
1. Read the safety information in “Safety” on page vii and “Installation
guidelines” on page 35.
2. Touch the static-protective package that contains the non-hot-swap power
supply to any unpainted metal surface on the server; then, remove the power
supply from the package and place it on a static-protective surface.
3. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
4. Carefully turn the server on its side so that it is lying flat, with the cover facing
up.
Attention: Do not allow the server to fall over.
5. Remove the side cover (see “Removing the side cover” on page 38).
6. Remove the air baffle (see “Removing the air baffle” on page 39).
7. Remove the heat sink (see “Removing the microprocessor and heat sink” on
page 300).
Figure 48. Syringe
72 System x3100 M5 Type 5457: Installation and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM x3100 M5 Type 5457 and is the answer not in the manual?

IBM x3100 M5 Type 5457 Specifications

General IconGeneral
BrandIBM
Modelx3100 M5 Type 5457
CategoryServer
LanguageEnglish

Related product manuals