13
IDS 1632 User Manual 700-256-01I Issued March 2009
9. Bypassing Zones
The term BYPASS is used to describe a zone which has been deactivated; i.e. violation of a
bypassed zone is ignored and will not cause an alarm condition.
Once the system is armed it is not possible to bypass zones.
All bypassed zones will be automatically cancelled each time the panel is disarmed and must be
re-bypassed before the next arming.
9.1 Bypassing/Un-Bypassing a Zone
Hold down [9] key until the beep,
then enter [ZONE NUMBER] [*] [#]
1. Ensure that the panel is not armed (Armed LED OFF).
2. To enter bypass mode, hold down the [9] key for one second (until the keypad buzzer sounds).
The Away LED will flash, and bypassed zones will be indicated by lit zone LEDs.
3. Entering a zone number [ZONE NUMBER] [*] will toggle the corresponding LED. For example,
[2] [*] will turn LED 2 on (if it was off) and off (if it was on).
4. Turn on the LEDs corresponding to the zones you need to bypass. The LED zone indicators
should now indicate only the zones that you require bypassing.
5. Once satisfied with your selection, press the [#] key to exit the bypass mode.
NOTE:
Panic zones cannot be bypassed and remember that all bypassed zones are reset at every panel
disarm cycle.
10. Emergency Alarms
10.1 Fire Alarms
Hold down the [F] key until the beep
If the [F] key is pressed until the keypad beeps (approximately 1 second) a FIRE ALARM
condition will be activated.
The FIRE ALARM CONDITION may also be triggered by a smoke detector connected to an
appropriately programmed zone.
The siren will sound on and off repeatedly if programmed and the FIRE REPORTING CODE will
be transmitted to the monitoring company.
To silence the siren enter a valid [USER CODE].
10.2 Panic Alarms
Hold down the [P] key until the beep
If the [P] key is pressed until the keypad beeps (approximately 1 second) a PANIC ALARM
condition will be activated.
A PANIC ALARM may also be activated using any FIXED PANIC button or a REMOTE PANIC
button (if installed).