27
IDS 1632 User Manual 700-256-01I Issued March 2009
22. Controlling the IDS 1632 via Cellphone SMS
This functionality is only available when an IDS GPRS module is installed with the IDS 1632 Alarm Panel.
You can control your 1632 Alarm Panel on your premises from any part of the world with coverage that
supports your cellphone. Each command you send must include the word “code” (without the quotes),
followed by the user code and then the required instruction.
Spaces are ignored – so they can be included or left out - and the module is not case
sensitive, so upper-case, lower-case (or a mixture of the two) are all acceptable. More than one
command can be included in the same SMS. If a command is to be applied to more than one entity, for
example to bypass zones 2 and 5, the numbers can be listed with a „+‟ symbol between them, like so:-
code 1234 bypass 2+5
The following table lists the commands are supported:
Table 5 : SMS Commands
The number(s) of the partition(s) to arm.
The number(s) of the partition(s) to
disarm.
Disarm x accepted/rejected.
Bypass x accepted/rejected.
The zone(s) to un-bypass.
Un-bypass x accepted/rejected.
The output(s) to activate.
The output(s) to deactivate.
Outputs to query the status of.
Status of listed outputs.
Optional - partitions to query status of.
Status of listed partitions.
If none are listed,
status of all partitions.
Another cell phone number to also
receive the panel response.
Panel sends response to this
number too
The panel responses will be sent to the originating cell phone, to the number programmed as SMS user
number 1 (if they are different), and to the response number (if specified).