22
IDS 1632 User Manual 700-256-01I Issued March 2009
4. Press the [2] key followed by the [*] key.
5. Press [1] or [2] for the required profile.
6. Press [*] to enter. The buzzer will give a long beep.
7. Program STAY and BUZZ zones for the profile (See pages 28 and 29) or ARM the profile
15.2 How to Program Stay Zones
After selecting the required stay profile (Page 27),
Hold down the [3] key until the beep,
then enter [ZONE NUMBER] [*] [#]
1. Select the required stay profile (See Page 21)
2. Hold down the [3] key until the keypad buzzer sounds. The AWAY indicator will flash indicating
that the panel is in the Stay zone programming mode.
3. Entering a [ZONE NUMBER] will toggle the corresponding LED. For example, [2] [*] will turn
LED 2 on (if it was off) and off (if it was on). (*Flashing zone LED‟s indicate zones that have been
set as Buzz zones and therefore cannot be changed in this menu)
4. Turn on the LED‟s corresponding to the zones you need to be Stay zones. The LED zone
indicators should now indicate only the zones that you require to be Stay zones.
5. Once satisfied with your selection, press the [#] key to exit the Stay zone mode.
NOTE:
Panic zones cannot be selected as Stay zones.
*Buzz zones cannot be selected as Stay zones. The Buzz status must be cleared first.
16. Buzz Zones
Violation of a buzz zone when Stay Armed will cause the keypad buzzer to sound for a period of 30
seconds during which time a valid user code must be entered. If a valid user code is not entered during
this period the system will register an alarm condition. This feature helps prevent unnecessary false
alarms.
NOTE:
If an Entry/Exit zone is programmed as a buzz zone, violation of the Entry/Exit zone (when the panel is
Stay Armed) will cause the keypad buzzer to sound for the duration of the entry delay time (in place of the
default 30 seconds). This, if the panel is stay armed, allows the user to enter the premises and disarm the
panel. If it is not programmed as a Buzz zone, the alarm will be triggered immediately. If the panel was
armed using the [6] key (Stay Arm and Go) violation of the Entry/Exit zone will always start the Entry/Exit
delay.
16.1 How to Program a Buzz Zone
After selecting the required stay profile (Page 21),
Hold down the [4] key until the beep,
then enter [ZONE NUMBER] [*] [#]
1. Select the required stay profile (See Page 21)
2. Hold down the [4] key until the keypad buzzer sounds. The AWAY indicator will flash indicating
that the panel is in the Buzz zone programming mode.