23
IDS 1632 User Manual 700-256-01I Issued March 2009
3. Entering a [ZONE NUMBER] will toggle the corresponding LED. For example, [2] [*] will turn
LED 2 on (if it was off) and off (if it was on). (*Flashing zone LED‟s indicate zones that have been
set as Stay zones and therefore cannot be changed in this menu)
4. Turn on the LED‟s corresponding to the zones you need to be Buzz zones. The LED zone
indicators should now indicate only the zones that you require to be Buzz zones.
5. Once satisfied with your selection, press the [#] key to exit the Buzz zone mode.
NOTE:
Panic zones cannot be set as Buzz zones
17. Chime Zones
The chime mode allows the user to monitor nominated zones while the system is disarmed. The keypad
buzzer will sound five times when the nominated zone is violated - the siren will NOT sound and no alarm
condition will be reported.
Example:
If you wish to know each time someone enters or exits the front door of your office program this zone as a
chime zone, the keypad will beep each time someone opens the front door.
17.1 How to Program Chime Zones
Hold down the [2] key until the beep,
then enter [ZONE NUMBER] [*] [#]
1. Select the required stay profile (See Page 21)
2. Hold down the [2] key until the keypad buzzer sounds. The AWAY indicator will flash indicating
that the panel is in the Chime zone programming mode.
3. Entering a zone number will toggle the corresponding LED. For example, [2] [*] will turn LED 2
on (if it was off) and off (if it was on).
4. Turn on the LED‟s corresponding to the zones you need to be CHIME zones. The LED zone
indicators should now indicate only the zones that you require to be CHIME zones.
5. Once satisfied with your selection, press the [#] key to exit the CHIME zone mode.
18. Viewing Trouble Conditions
Hold down the [7] key until the beep
The user is alerted to a trouble condition via a flashing power LED. It is also possible to enable a trouble
beep. (Ask your Alarm Panel Installer)
If the trouble beep has been enabled, the keypad buzzer will sound to alert the user that a
trouble condition has occurred. Press the [#] key to silence the buzzer.
Hold down the [7] key for two seconds. The ARMED, AWAY and READY indicators will be
flashing simultaneously showing that the keypad is in the TROUBLE VIEW MODE. Refer to the Table 3 to
find the significance of each lit zone LED. The system will automatically exit the TROUBLE VIEWING
MODE after one minute. (Alternately to exit this mode press [#]).
NOTE:
Certain trouble conditions will only clear once the trouble condition has restored. To cancel the beeping
without viewing the trouble conditions, press [#] key.