29 - IE
INSTALLERUSERTECHNICIAN
3.20 COMBUSTION PARAMETERS.
G20 G30 G31
Supply pressure mbar (mm H
2
O) 20 (204) 29 (296) 37 (377)
Victrix X 12 2 I
Gas nozzle diameter mm 3.70 2.80 2.80
Flue ow rate at nominal heat output kg/h 19 17 20
Flue ow rate at min heat output kg/h 3 3 3
CO
2
at Nom Q./Min. % 9.50 / 8.85 12.50 / 11.60 10.60 / 10.20
CO with 0% O
2
at Nom Q /Min. ppm 110 / 4 440 / 4 115 / 1
NO
X
with 0% O
2
at Nom Q /Min. mg/kWh 48 / 13 185 / 20 85 / 25
Flue temperature at nominal output °C 56 63 57
Flue temperature at minimum output °C 58 64 59
Victrix X 24 2 I
Gas nozzle diameter mm 5.60 4.00 4.00
Flue ow rate at nominal heat output kg/h 42 38 43
Flue ow rate at min heat output kg/h 5 5 5
CO
2
at Nom Q./Min. % 9.50 / 8.90 12.30 / 11.60 10.60 / 10.20
CO with 0% O
2
at Nom Q /Min. ppm 200 / 4 650 / 4 190 / 3
NO
X
with 0% O
2
at Nom Q /Min. mg/kWh 47 / 15 170 / 30 45 / 18
Flue temperature at nominal output °C 57 63 57
Flue temperature at minimum output °C 58 64 59

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas VICTRIX X 12-24 2I and is the answer not in the manual?

Immergas VICTRIX X 12-24 2I Specifications

General IconGeneral
BrandImmergas
ModelVICTRIX X 12-24 2I
CategoryBoiler
LanguageEnglish

Related product manuals