5 Parameter Table
- 31 -
■
Group F4: Input Terminals
Para� No� Para� Name Setting Range Unit Default Commission
F4-00 DI1 function selection 0 to 59 N�A� 1
F4-01 DI2 function selection 0 to 59 N�A� 4
F4-02 DI3 function selection 0 to 59 N�A� 9
F4-03 DI4 function selection 0 to 59 N�A� 12
F4-04 DI5 function selection 0 to 59 N�A� 13
F4-05 DI6 function selection 0 to 59 N�A� 0
F4-06 DI7 function selection 0 to 59 N�A� 0
F4-07 DI8 function selection 0 to 59 N�A� 0
F4-08 DI9 function selection 0 to 59 N�A� 0
F4-09 DI10 function selection 0 to 59 N�A� 0
F4-10 DI lter time 0�000 to 1�000 s 0�010
F4-11 Terminal command mode 0: Two-wire control mode 1
1: Two-wire control mode 2
2: Three-wire control mode 1
3: Three-wire control mode 2
N�A� 0
F4-12 Terminal UP/DOWN rate 0�01 to 65�535 Hz/s 1�000
F4-13 AI curve 1 minimum input 0�00 to F4-15 V 0�00
F4-14 Corresponding setting of AI
curve1 minimum input
-100�0 to100�0 % 0�0
F4-15 AI curve 1 max input F4-13 to 10�00 V 10�00
F4-16 Corresponding setting of AI
curve1 max input
-100�0 to 100�0 % 100�0
F4-17 AI1 lter time 0�00 to 10�00 s 0�10
F4-18 AI curve 2 minimum input 0�00 to F4-20 V 0�00
F4-19 Corresponding setting of AI
curve2 minimum input
-100�0 to 100�0 % 0�0
F4-20 AI curve 2 max input F4-18 to 10�00 V 10�00
F4-21 Corresponding setting of AI
curve2 max input
-100�0 to 100�0 % 100�0
F4-22 AI2 lter time 0�00 to 10�00 s 0�10
F4-23 AI curve 3 minimum input -10�00 to F4-25 V -10�00
F4-24 Corresponding setting of AI
curve3 minimum input
-100�0 to100�0 % -100�0
F4-25 AI curve 3 max input F4-23 to 10�00 V 10�00
F4-26 Corresponding setting of AI
curve3 max input
-100�0 to 100�0 % 100�0
F4-27 AI3 lter time 0�00 to10�00 s 0�10
F4-28 Pulse minimum input 0�00 to F4-30 kHz 0�00
F4-29 Corresponding setting of
pulse minimum input
-100�0 to 100�0 % 0�0
F4-30 Pulse max input F4-28 to 20�00 kHz 20�00
F4-31 Corresponding setting of
pulse max input
-100�0 to 100�0 % 100�0
F4-32 Pulse lter time 0�00 to 10�00 s 0�10
F4-33 AI curve selection 111 to 555 N�A� 321