Chapter 6 Description of Function Codes
- 76 -
position feedback signal is output. It is used together with F9-12 (Door position feedback signal
output).
Group F7: Demonstration Function Parameters
Function Code Parameter Name Setting Range Default Min. Unit
F7-00
Door open limit holding time in
demonstration mode
1.0–999.9s 2.0s 0.1s
It is used to set the time from torque holding upon door open limit to reverse door close in
demonstration mode. Set this parameter based on actual demonstration requirements.
Function Code Parameter Name Setting Range Default Min. Unit
F7-01
Door close limit holding time in
demonstration mode
1.0–999.9s 2.0s 0.1s
It is used to set the time from torque holding upon door close limit to forward door open in
demonstration mode. Set this parameter based on actual demonstration requirements.
Function Code Parameter Name Setting Range Default Min. Unit
F7-02
Actual door open and close times in
demonstration mode
0–9999 0 1
It is used to record the times of door open and close for demonstration. The parameter value
is stored automatically at power failure. Upon door open/close limit after power-on again, the
value is calculated by adding 1 for each door open/close to the original value.
The demonstration mode is an automatically cyclic running process, described as follows:
1. After you press
or
, demonstration running is started.
2. The door machine closes the door at a low speed, and opens the door based on the
running curve upon door close limit.
3. The door machine starts timing upon door open limit, and automatically performs reverse
door close after the time reaches the value set in F7-00.
4. The door machine starts timing upon door close limit, and performs reverse door open
after the time reaches the value set in F7-01.
5. This process is repeated until you press
to stop the controller. Then the
demonstration process ends.
Demonstration running can be performed in speed control or distance control mode. It applies
to demonstration and aging test.
Function Code Parameter Name Setting Range Default Min. Unit
F7-03
Limit of door open and close times in
demonstration mode
0–9999 0 1