Chapter 6 Description of Function Codes
- 85 -
Function Code Parameter Name Setting Range Default Min. Unit
FA-19 Input signal display * * *
It is used to view the input signal state. When an input signal is active, the corresponding LED
is ON. The LEDs are arranged as 1, 2, 3, and 4 from left to right.
A
B
C
D
E
F
G
DP
A
B
C
D
E
F
G
DP
A
B
C
D
E
F
G
DP
A
B
C
D
E
F
G
DP
1
2 3
4
The meaning of each segment is dened in the following table.
Segment
(LED1)
Meaning of ON
Segment
(LED2)
Meaning of ON
Segment
(LED3 &
LED4)
Meaning
of ON
A
Door open command
active
A Reserved
Reserved Reserved
B
Door close command
active
B Light curtain signal active
C
External reset signal
active
C Safety edge signal active
D
Forbid terminal input
during door open active
D
Door open limit signal
active
E
Forbid terminal input
during torque holding
active
E
Door close limit signal
active
F
Low speed door open
input active
F
Door open slow-down
signal active
G
Fire emergency input
active
G
Door close slow-down
signal active
DP Reserved DP Door lock signal active
Function Code Parameter Name Setting Range Default Min. Unit
FA-20 Output signal display * * *
It is used to view the output signal state. When an input signal is active, the corresponding
LED is ON. The LEDs are arranged as 1, 2, 3, and 4 from left to right.
A
B
C
D
E
F
G
DP
A
B
C
D
E
F
G
DP
A
B
C
D
E
F
G
DP
A
B
C
D
E
F
G
DP
1
2
3
4