EasyManuals Logo
Home>Intel>Server Board>E42249-003

Intel E42249-003 Product Specification

Intel E42249-003
119 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
Intel
®
Server Board S5500BC TPS Platform Management
Revision 1.0 Intel order number: E42249-003 51
4.4.6 ACPI Mode Notification
The BIOS notifies the BMC when the system enters and exits ACPI mode. The BMC, in turn,
notifies the ME. The NM power-limiting functionality is only available when the system is
operating in ACPI mode (an ACPI-compliant operating system is running).
4.4.7 Persistence Across Boots
Data passed to the ME will persist across boots, but will not persist across AC power loss.
4.5 Power Management Bus (PMBUS)
The BMC firmware implements power-management features based on the Power Management
Bus (PMBus) 1.1 Specification. The following sensor types are supported for systems that
contain PMBus-compliant power supplies and a PMBus-compliant power distribution board.
Power Supply Input Power Sensor
Power Supply Output Current Sensor
Power Supply Temperature Sensor

Table of Contents

Other manuals for Intel E42249-003

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel E42249-003 and is the answer not in the manual?

Intel E42249-003 Specifications

General IconGeneral
BrandIntel
ModelE42249-003
CategoryServer Board
LanguageEnglish

Related product manuals