Installation
Copyright ©ITECH Electronic Co., Ltd. 29
NOTE
The T8230-350-180 consists of two 15kVA in parallel mode. Connect the Remote
sense terminals of master module. The wiring method is the same as other
models.
The connection diagram of single phase is shown as follow:
NOTE
When the input voltage is DC voltage, the input terminal L is positive, and N is negative.
When used as a three-phase power output, he Y connection mode is used
as an example, The connection diagram is shown as follow:
When Delta connection mode is selected in the system menu, the N wire
does not need to be connected. the N line of the Sense terminal needs to
be connected to the N terminal of the output terminal.