System Commands
Copyright © Itech Electronic Co., Ltd. 37
SYSTem:CLEar
This action command is used to clear the Error Queue of messages.
Command Syntax
SYSTem:CLEar
Parameters
None
Examples
SYST:CLE
Related Commands
SYST:ERR?
SYSTem:LOCal
This command places the electronic load in local mode during RS-232
operation. The front panel keys are functional.
Command Syntax
SYSTem:LOCal
Parameters
None
Examples
SYST:LOC
Related Commands
SYST:REM SYST:RWL
SYSTem:REMote
This command places the electronic load in remote mode during RS-232
operation. This disables all front panel keys except the Local key. Pressing the
Local key while in the remote state returns the front panel to the local state.
Command Syntax
SYSTem:REMote