STATus Subsystem
Copyright © Itech Electronic Co., Ltd. 39
Chapter5 STATus Subsystem
These commands program the electronic load status registers. The electronic
load has five groups of status registers; Channel Status, Channel Summary,
Questionable Status, Standard Event Status, and Operation Status. Refer to
“Programming the Status Registers” for more information.
STATus:CHANnel?
Channel Specific
This query returns the value of the Channel Event register. The Event register is
a read-only register which holds (latches) all events that are passed into it.
Reading the Channel Event register clears it.
Query Syntax
STATus:CHANnel[:EVENt]?
Parameters
None
Examples
STAT:CHAN:EVEN?
Returned Parameters
<NR1> (register value)
Related Commands
*CLS
STATus:CHANnel:CONDition?
Channel Specific
This query returns the value of the Channel Condition register. The particular
channel must first be selected by the CHAN command.
Query Syntax
STATus:CHANnel:CONDition?
Parameters
None

Table of Contents

Other manuals for ITech IT8700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT8700 Series and is the answer not in the manual?

ITech IT8700 Series Specifications

General IconGeneral
BrandITech
ModelIT8700 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals