35
Exing Priming Mode
The system will automacally enter the normal heang mode and filtering at the end of the
priming mode, which lasts 4-5 minutes.
You can manually exit Priming Mode by pressing the “Back” buon on the Priming Mode
Screen. Note that if you do not manually exit the priming mode as described above, the prim-
ing mode will be automacally terminated aer 4-5 minutes. Be sure that the pump(s) have
been primed by this me.
Once the system has exited Priming Mode, the top side panel will display the Main Screen,
but the display will not show the water temperature yet. This is because the system requires
approximately 1 minute of water flowing through the heater to determine the water temper-
ature to display it.
10.5 Spa Behaviour
Pumps
On the Spa Screen, select a “Jets” buon once to turn the pump on or off, and to shi be-
tween low and high speeds if equipped. If le running, the pump will turn off aer a me-out
period of 30 minutes.
Non-Circ Systems
The low-speed of pump 1 runs when any other pump is on. If the swim spa is in Ready Mode,
Pump 1 low may also acvate for at least 1 minute every 30 minutes to detect the swim spa
temperature (polling) and then to heat to the set temperature if needed. When the low-
speed turns on automacally, it cannot be deacvated from the panel, however the high
speed may be started.
Filtraon and Ozone
On non-circ systems, Pump 1 low and the ozone generator will run during filtraon. The sys-
tem is factory-programmed with one filter cycle that will run in the evening (assuming the
me-of-day is properly set) when energy rates are oen lower. The filter me and duraon
are programmable. A second filter cycle can be enabled as needed. At the start of each filter
cycle, the pumps will run briefly to purge the plumbing to maintain good water quality.