7 Load handler emergency lowering
WARNING!
Load handler emergency lowering
u
Instruct other people to move out of the hazardous area of the truck during
emergency lowering.
u
Never step or stand underneath a raised load handler.
u
Only operate the emergency lowering valve when standing next to the truck.
u
When the load handler is in the racking, emergency lowering is not permitted.
u
Report any defects immediately to your supervisor.
u
Mark defective truck and take out of service.
u
Do not return the industrial truck to service until you have identified and rectified
the fault.
7.1 ERC 212/212z
Load handler emergency lowering
Requirements
– Load handler is not in the rack.
Tools and Material Required
– Allen key 5 mm
Procedure
• Set the key switch (11) to “0”.
• Press the emergency disconnect switch
(18), see page 80.
• Lift off the front panel, see page 180
• Undo the screw on the valve block (70) (max. 3 turns).
The load handler is lowered.
Z
After carrying out the emergency lowering, turn in the screw on the valve block (70)
fully.
111