LED display
(50)
Green LED (charge status)
Lit Charging complete, battery full. (Charge interval, float
or compensation charge).
Flashes slowly Charging.
Rapid flash Display at beginning of charge or after setting a new
characteristic curve. Number of flash pulses
corresponds to the characteristic curve set.
Red LED (fault)
Lit Overtemperature. Charging is interrupted.
Flashes slowly Safety charging time exceeded. Charging is cancelled.
Mains must be disconnected for charging to restart.
Rapid flash Invalid characteristic curve setting.
Compensation charge
The compensation charge starts automatically when charging is complete.
Partial charging
The charger is designed to automatically adapt to partially charged batteries. This
keeps battery wear to a minimum.
55
04.19 en-GB