11
STANDARDS FOR DRIVE CONVERTERS / CONTROL CABINETS
Standards for drive converters / control cabinets
Product standards that apply directly to the drive converter
EN 61800-2 Adjustable speed electrical power drive systems - Part 2: General requirements -
Ratingspecicationsforlowvoltageadjustablefrequencya.c.powerdrive
systems (VDE 0160-102, IEC 61800-2)
EN61800-3 Speed-adjustableelectricaldrives.Part3:EMCrequirementsandspecictest
methods (VDE 0160-103, IEC 61800-3)
EN 61800-5-1 Adjustable speed electrical power drive systems - Part 5-1: Safety requirements
-Electrical,thermalandenergy(IEC61800-5-1);GermanversionEN61800-5-1
EN 61800-5-2 Adjustable speed electrical power drive systems - Part 5-2: Safety Requirements
- Functional (IEC 22G/264/CD)
UL 61800-5-1 American version of the EN 61800-5-1 with „National Deviations“
Basic standards to which drive converter standards refer directly
EN55011 Industrial,scienticandmedicalequipment-Radiofrequencydisturbance
characteristics-Limitsandmethodsofmeasurement(CISPR11);German
version EN 55011
EN 55021 Interference to mobile radiocommunications in the presence of impulse noise -
Methods of judging degradation and measures to improve performance (IEC/
CISPR/D/230/FDIS);GermanversionprEN55021
EN 61000-2-1 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Descrip-
tion of the environment - Electromagnetic environment for low-frequency
conducted disturbances and signalling in public power supply systems
EN61000-2-4 Electromagneticcompatibility(EMC)-Part2-4:Environment;Compatibility
levels in industrial plants for low-frequency conducted disturbances (IEC 61000-
2-4);GermanversionEN61000-2-4
EN 61000-4-2 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement
techniques-Electrostaticdischargeimmunitytest(IEC61000-4-2);German
version EN 61000-4-2
EN 61000-4-3 Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement
techniques-Radiated,radio-frequency,electromagneticeldimmunitytest(IEC
61000-4-3);GermanversionEN61000-4-3
EN 61000-4-4 Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement
techniques-Electricalfasttransient/burstimmunitytest(IEC61000-4-4);
German version EN 61000-4-4
EN 61000-4-5 Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement
techniques-Surgeimmunitytest(IEC61000-4-5);GermanversionEN61000-4-5
EN 61000-4-6 Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement
techniques - Immunity to conducted disturbances, induced by radio-frequency
elds(IEC61000-4-6);GermanversionEN61000-4-6
EN 61000-4-34 Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement
techniques - Voltage dips, short interruptions and voltage variations immunity
tests for equipment with mains current more than 16 A per phase (IEC 61000-4-
34);GermanversionEN61000-4-34
EN 61000-6-7 Electromagnetic compatibility (EMC) - Part 6-7: Generic standards - Immunity
requirements for equipment intended to perform functions in a safety-related
system (functional safety) in industrial locations (IEC 61000-6-7).