EasyManuals Logo
Home>Keithley>Power Supply>2260B-80-13

Keithley 2260B-80-13 User Manual

Keithley 2260B-80-13
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
OPERATION
43
Basic Operation
This section describes the basic operations required to operate the
power supply.
Setting OVP/OCP → from page 43
CV mode → from page 45
CC mode → from page 48
Display modes → page 51
Panel lock → page 52
Remote sensing → from page 53
Before operating the power supply, please see the Getting Started
chapter, page 7.
Setting OVP/OCP Levels
The OVP level has a selectable range of 10% to
110% of the rated output voltage. The OCP
level has a selectable range 10%~ 110% of the
rated output current, alternatively the OCP
level can also be turned off. The OVP and OCP
level is set to 110% by default.
When one of the protection measures are on,
ALM is shown on the panel display. By default,
the power switch will turn off when any of the
protection levels are tripped.
ALM
V
A