EasyManuals Logo
Home>Keithley>Power Supply>2260B-80-13

Keithley 2260B-80-13 User Manual

Keithley 2260B-80-13
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #97 background imageLoading...
Page #97 background image
2260B Series User Manual
94
F-93
0 = Master/Local
1 = Master/Parallel1
2 = Master/Parallel2
3 = Slave/Parallel
4 = Slave/Series
External Out
Logic
Sets the external logic as active high or low.
F-94
0= High ON, 1 = Low ON
Power Switch Trip
Turns the power off if enabled when the
protection settings are tripped.
F-95
1 = Disable, 0 = Enable
Calibration
Programmable
Calibration
The calibration password is used to access the
local mode calibration or other special
functions. The password used determines
which function is accessed. Please see your
distributor for details.
F-00
0000 ~ 9999
Setting Normal Function Settings
The normal function settings (F-01~F-61, F-
88~F-89) can be easily configured with the
Function key.
Ensure the load is not connected.
Ensure the output is off.
Note
Function setting F-89 (Show Version) can only be
viewed, not edited.
Configuration settings F-90~F-95 cannot be edited
in the Normal Function Settings. Use the Power
On Configuration Settings. See page 96 for details.

Table of Contents

Other manuals for Keithley 2260B-80-13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2260B-80-13 and is the answer not in the manual?

Keithley 2260B-80-13 Specifications

General IconGeneral
BrandKeithley
Model2260B-80-13
CategoryPower Supply
LanguageEnglish

Related product manuals