CONFIGURATION
89
Sets the rising current slew rate. Only
applicable if V-I Mode is set to CC Slew Rate
Priority.
0.01A/s~72.00A/s (2260B-30-36)
0.1A/s~144.0A/s (2260B-30-72)
0.01A/s~27.00A/s (2260B-80-13)
0.01A/s~54.00A/s (2260B-80-27)
Falling Current
Slew Rate
Sets the falling current slew rate. Only
applicable if V-I Mode is set to CC Slew Rate
Priority.
0.01A/s~72.00A/s (2260B-30-36)
0.1A/s~144.0A/s (2260B-30-72)
0.01A/s~27.00A/s (2260B-80-13)
0.01A/s~54.00A/s (2260B-80-27)
Internal
Resistance
Settings
Sets the internal resistance of the power supply.
0.000Ω ~0.833Ω (2260B-30-36)
0.000Ω ~0.417Ω (2260B-30-72)
0.000Ω ~5.926Ω (2260B-80-13)
0.000Ω ~2.963Ω (2260B-80-27)
Bleeder control turns ON/OFF the bleeder
resistor. Bleeder resistors discharge the filter
capacitors after power is turned off as a safety
measure.
Turns the buzzer sound on or off. The buzzer is
associated with alarm sounds and keypad entry
sounds.