6-21
Resetting
Over-Voltage
Protection
If
the OVP
circuit
functions while
the PS
Series
is
running,
the
output
is
turned
off,
the OUTPUT
LED ®
goes
off,
and
the
OVP LED ©
goes
on.
OUTPUT
LED
goes
off.
OVP
LED
goes
on.
OResetting
procedure
1
Deactivate
the POWER
switch
(D on the
front
panel
(switch released).
When
all
LED
9
s
has
gone
off,
press
the POWER
switch
to
activate
it
(switch
depressed).
The OVP
function
is
reset.
OResetting
procedure
2
(In
case that
the
main
relay
is
remote-controlled)
DDeactivate
the
external switch
connected
between
pins
18 and 19 of the
control terminal block
Ji
© on the
rear panel.
Al
1
digits
on the
voltmeter
(2) and
ammeter
(3) on the
front
panel
go
off,
except
the
decimal
points.
The OVP LED ©
also
goes
off,
and the OVP
function
is
reset.
2)Then,
activate
the
external switch again.
The PS
Series
becomes
ready
for
operation
in
approx.
three
seconds.
(See
the
figure
on the
following
page.)