6.10.5 Balances appropriate for verification (only ARJ/PRJ models)
Balances appropriate for verification are provided with EU/OIML approval or meet the EU
regulations for verified balances.
The balance program and certain functions of the weighing output differ from the standard
program in the case of balances which are appropriate for verification – in accordance
with EU regulations.
General:
According to EU guideline 90/384/EEC, balances must be verified officially if they are to
be used as follows (in a legally regulated area):
a) For commercial transactions if the price of goods is determined by weighing.
b) For the production of medicines in pharmacies as well as for analyses in the
medical and pharmaceutical laboratory.
c) For official purposes.
d) For the production of packed goods.
In case of doubt, please contact your local weights and measures office.
Verification information
For those balances marked as appropriate for verification in the technical data, an EC
type approval is available. In the event that the balance is used in an area subject to
verification as described above, it must be officially verified and re-verified at regular
intervals.
Re-verification of a balance is carried out in compliance with the respective legal
provisions of that particular country. The period of verification validity for balances in
Germany, for example, is normally 2 years.
The legal provisions of the country of use are to be observed.
After the verification process, the scale is sealed at the marked points.
Without the “seal”, the verification of the scale is not valid.
Balances appropriate for verification are provided with EU approval or meet the EU
regulations for verified balances.
The balance program and certain functions of the weighing output differ from the standard
program in the case of balances which are appropriate for verification – in accordance
with EU regulations.
NOTE
If a circle appears in the main display of a verified balance, then the displayed value is not
verified.
In balances of class (I) the circle also denotes the warm-up phase.
Your KERN trader will be happy to assist you at any time if you have any questions on the
verification of the balance or on working with verified balances.