Temperature
When the water temperature is over 100 °C (212 °F)
1. Check to see if dirt, dust, etc. are caught in the ra-
diator net or the radiator tube and fin.
2. Check to see if the fan belt has become loose.
3. Check to see if fur has formed in the pipes of the
radiator.
4. Check to see if the thermostat is working properly.
Remove the thermostat and dip it into hot water,
and then check to see if it opens at the temperature
marked on the thermostat. If the thermostat does
not work properly, replace with new one.
NOTE :
Never run engine with filter element removed.
Clean the Radiator Net
When the tractor is used in wet fields, grass seeds
may get caught, or mud may splash into the radiator
net. Also when used at night, insects may become
caught on the net. In such cases remove the net and
clean it well.
623O919A
9.11 Battery
Never remove the battery cap while the
engine is running. Keep electrolyte
away from eyes, hands and clothes. If
you are spattered with it, wash it away
completely with water. Mishandling the
battery shortens the service life and
adds to maintenance costs. Be sure to
handle it correctly so that it will develop
its full potential performance.
Gas given off by batteries is explosive.
To avoid injury or battery damage,
avoid sparks near the batteries.
WARNING